SL 10-85G3
SL 14-115G3
SL 20-160G3
SL 30-199G3
Residential High Efficiency Condensing Boilers
Dual piping options on residential models
Features
Technical Data
Connections
Documentation
Documentation (Fr)
Features
Touch Screen Boiler Controller: • Express setup • Remote monitoring & diagnostics • Easy USB programmability • True native BACnet • Intuitive alert system • Simplified load pairing • Visible flame current. |
· Better efficiency up to 96% AFUE. |
· Multiple zone pump control – up to 4 zones. Replacing the need for external pump controls. |
· PVC/CPVC/PPs approved – venting up to 480ft on the SL 10-85 G3 & SL 14-115G3. |
· MFZ Technology: Patented moisture management system. Protects and ensures long life for all components in the boiler. |
· Built-in CSA/UL approved LWCO and manual reset high limit. |
· Connect your IBC Indirect Water Tank directly to the boiler without a primary loop. |
· Turndown ratio of up to 8:1 means you have the power to heat your home in the coldest weather, yet reduce short cycling when the weather is mild. |
· Built-in outdoor reset control of water temperature. |
· Reverse flow detection. |
· 5 Year limited manufacturer’s parts warranty. |
· Limited lifetime residential heat exchanger warranty. |
Technical Data
Specifications | SL 10-85G3 | SL 14-115G3 | SL 20-160G3 | SL 30-199G3 |
CSA Input (Natural Gas or Propane *) – MBH | 10.6 – 85 | 14 – 115 | 20 – 160 | 32 – 199 |
CSA Input (Natural Gas or Propane *) – KW | 3.10 – 24.9 | 4.10 – 33.7 | 5.86 – 46.9 | 9.37 – 58.3 |
CSA Output – MBH | 10.1 – 79 | 13.3 – 109 | 19.0 – 147 | 30 – 181.3 |
CSA Output – KW | 2.96 – 23 | 3.90 – 32 | 5.57 – 43.1 | 8.8 – 53.1 |
A.F.U.E | 96% | 95% | 95% | 95% |
Min gas pressure (Nat. Gas or Propane) – inch w.c. | 4 | 4 | 4 | 4 |
Max gas pressure (Nat. Gas or Propane) – inch w.c. | 14 | 14 | 14 | 14 |
Power (120Vac/60Hz) – Watts @ full fire – Watts ( without pumps) | 54 | 54 | 73 | 82 |
Weight (empty) – lbs/Kg | 85/39 | 85/39 | 102 / 46.3 | 152 / 69 |
Pressure vessel water content – USG/Liters | 2.47 / 9.35 | 2.47 / 9.35 | 1.72 / 6.51 | 5.09 / 19.3 |
Max boiler flow rate – USgpm | 14 | 14 | 19 | 22 |
Min boiler flow rate – USgpm | 2 | 2 | 4 | 6 |
Max operating pressure – psig | 30 | 30 | 30 | 30 |
Min water pressure – psig | 8 | 8 | 8 | 8 |
Approved installation altitude – ASL | 0 – 12,000 ft | 0 – 12,000 ft | 0 – 12,000 ft | 0 – 12,000 ft |
Ambient temperature – Low (°F/°C) | 32°F / 0°C | 32°F / 0°C | 32°F / 0°C | 32°F / 0°C |
Ambient temperature – High (°F/°C) | 122°F / 50°C | 122°F / 50°C | 122°F / 50°C | 122°F / 50°C |
Max relative humidity (non-condensing) | 90% | 90% | 90% | 90% |
Min water temperature (°F/°C) | 34°F / 1°C | 34°F / 1°C | 34°F / 1°C | 34°F / 1°C |
Max water temperature (electronic-limit) (°F/°C) | 190°F / 88°C | 190°F / 88°C | 190°F / 88°C | 190°F / 88°C |
Max ΔT – supply / return (electronic fence) | 40°F | 40°F | 40°F | 40°F |
Maximum equivalent vent length, each side 2” | 100′ | 100′ | 35′ | N/A |
Maximum equivalent vent length, each side 3” | 240′ | 240′ | 170′ | 150′ |
Exhaust pipe size | SL 10-85 G3 / SL 14-115G3 | SL 20-160G3 | SL 30-199G3 |
Sched.40; Rigid PPs | (each side) | (each side) | (each side) |
2” | 100’ | 35’ | Not allowed |
3” | 240’ | 170’ | 150’ |
90° long sweep elbow | Allow 5’ equivalent | Allow 5’ equivalent | Allow 5’ equivalent |
90° vent elbow | Allow 8’ equivalent | Allow 8’ equivalent | Allow 8’ equivalent |
45° elbow | Allow 3’ equivalent | Allow 3’ equivalent | Allow 3’ equivalent |
PPs 87-90° elbows | Allow 8’ equivalent | Allow 8’ equivalent | Allow 8’ equivalent |
2” SS Sidewall Terminal | Allow 20’ equiv. of 2” Sched 40 | Not allowed | Not allowed |
3” SS Sidewall Terminal | Allow 20’ equiv. of 3” Sched 40 | Allow 20’ equiv. of 3” Sched 40 | Allow 20’ equiv. of 3” Sched 40 |
Flexible PPs | |||
3” Flexible | 45’ (max) | 45’ (max) | 30’ (max) |
Actual lineal x 1.2 = equivalent | Actual lineal x 2 = equivalent | Actual lineal x 3.3 = equivalent |
-Fuel Conversion kit included
-Boilers are shipped with a 30 psi relief valve
Connections
SL 85 / 115 G3 | SL 160 G3 | SL 199 G3 | |
Flue Outlet | 3″ Schedule 40 or 3″ PPs (80mm) | ||
Combustion Air | 3″ Schedule 40 or 3″ PPs (80mm) | ||
LCD Display | 2¼” x 4″ | 2¼” x 4″ | 2¼” x 4″ |
Water Outlet | 1″ NPT-M | 1″ NPT-M | 1¼” NPT-M |
Water Inlet | 1″ NPT-M | 1″ NPT-M | 1¼” NPT-M |
Knock-Outs (8) | 1/2″ | 1/2″ | 1/2″ |
Gas Inlet | 1/2″ NPT-F | 1/2″ NPT-F | 1/2″ NPT-F |
Condensate Outlet | 3/4″ Hose | 3/4″ Hose | 3/4″ Hose |
Documentation
List of Manuals
↓ SL Series Installation & Operating Instruction Manual |
↓ SL Series User Manual |
↓ Quick Reference Installation Guide |
List of Literature
↓ SL Series Sales Brochure |
↓ Engineering Submittal |
Documentation (Fr)
Liste des manuels
↓ Instructions d’ Installation et Mode d’Emploi |
↓ Manuel d’Utilisation |
↓ Unité de commande de chaudière V-10 – écran du système de nayigation original |
↓ Fiche de référence pour l’installation |
Liste de littérature
↓ Brochure de vente – Bientôt |